Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J. oral res. (Impresa) ; 11(5): 1-12, nov. 23, 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1435341

RESUMO

In Purpose: The fabrication technique can influence the mechanical properties of Cobalt-Chromium (Co-Cr) dental alloys. Hence, the present study aims to determine the corrosion resistance and thermal expansion of alloys manufactured using three contemporary techniques. Material and Methods: A total of nine specimens of Co-Cr alloy were prepared according to ISO 22674 by each one of the three manufacturing processes (three in each process); conventional casting, direct metal laser sintering (DMLS) and milling (MIL). All these specimens were tested for coefficient of thermal expansion and corrosion resistance. The data was tabulated and analyzed statistically. Results: The difference in the thermal expansion of alloys fabricated using three techniques was non-significant at almost all the temperatures from 50 ºC to 950 ºC (p>0.05), except 450 ºC and 600 °C. The polarization resistance of specimens manufactured using the conventional method was more compared to DMLS and MIL at pH 5 (Conventional>MIL>DMLS) (p<0.001). Conclusion: The thermal expansion behavior of alloys manufactured using the three selected techniques were similar, whereas, at acidic pH, the corrosion resistance of conventional and MIL were better than the DMLS.


Antecedentes: La técnica de fabricación puede influir en las propiedades mecánicas de las aleaciones dentales de cobalto-cromo (Co-Cr). Por lo tanto, el presente estudio tiene como objetivo determinar la resistencia a la corrosión y la expansión térmica de aleaciones fabricadas con tres técnicas contemporáneas. Material y Métodos: Se prepararon un total de nueve probetas de aleación de Co-Cr según ISO 22674 por cada uno de los tres procesos de fabricación (tres en cada proceso); fundición convencional, sinterización directa de metal por láser (DMLS) y fresado (MIL). Todos estos especímenes fueron probados para determinar el coeficiente de expansión térmica y la resistencia a la corrosión. Los datos fueron tabulados y analizados estadísticamente. Resultados: La diferencia en la dilatación térmica de las aleaciones fabricadas con las tres técnicas no fue significativa en casi todas las temperaturas desde 50ºC hasta 950ºC (p>0,05), excepto 450ºC y 600ºC. La resistencia a la polarización de las muestras fabricadas con el método convencional fue mayor en comparación con DMLS y MIL a pH 5 (Convencional>MIL>DMLS) (p<0, 0 01). Conclusión: El comportamiento de expansión térmica de las aleaciones fabricadas con las tres técnicas seleccionadas fue similar, mientras que, a pH ácido, la resistencia a la corrosión de la convencional y la MIL fue mejor que la de la DMLS.


Assuntos
Humanos , Temperatura , Ligas de Cromo , Corrosão , Ligas Dentárias , Propriedades de Superfície , Técnicas In Vitro , Cromo/química , Cobalto/química , Lasers
2.
J Indian Prosthodont Soc ; 18(2): 161-167, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29692570

RESUMO

PURPOSE: The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. MATERIALS AND METHODS: 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled to form 8 simulations. After discretization, the contact stresses developed for 150 N vertical and 100 N oblique load applications were analyzed, using ABAQUS. By assessing damage initiation and shortest fatigue load on screw threads, the SL for 2.5, 5, and 10 lakh cyclic loads were estimated, using fe-safe program. The obtained values were compared for influence of connection design, abutment angulation, and screw length. RESULTS: In straight abutment models, conical connection showed more damage (14.3%-72.3%) when compared to trilobe (10.1%-65.73%) at 2.5, 5, and 10 lakh cycles for both vertical and oblique loads, whereas in angulated abutments, trilobe (16.1%-76.9%) demonstrated more damage compared to conical (13.5%-70%). Irrespective of the connection type and abutment angulation, short screws showed more percentage of damage compared to long screws. CONCLUSIONS: The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws.

3.
Indian J Dent Res ; 23(1): 97-100, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22842258

RESUMO

Surgical resection is an established and common method for treatment of maxillofacial tumors. Such intervening surgery in this region may involve the destruction of antral, nasal, or orbital contents and jaws. Normally, the end result is a defect which may affect speech, swallowing, mastication and facial appearance. Prosthodontic restoration of functions and facial form is an excellent method in the replacement of missing parts and restoration of contour. Pertinent research in materials, designs and methods have resulted in whole array of possible prosthess that can be provided to meet specific patient needs. This case report describes the fabrication of definitive obturator prosthesis made of flexible acrylic resin on a chrome cobalt base.


Assuntos
Resinas Acrílicas/química , Materiais Dentários/química , Planejamento de Prótese Dentária , Maxila/cirurgia , Obturadores Palatinos , Adolescente , Ligas de Cromo/química , Planejamento de Dentadura , Prótese Parcial Removível , Feminino , Humanos , Neoplasias Maxilares/reabilitação , Neoplasias Maxilares/cirurgia , Osteossarcoma/reabilitação , Osteossarcoma/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...